BSSZX - NON-SHRINK GROUT, 1585
- MSDS: BSSZX
- Manufacturer: QUIKRETE CO
- Product Name: NON-SHRINK GROUT, 1585
- National Stock Number: 5610-00N042060
Product Identification
Product ID:NON-SHRINK GROUT, 1585
MSDS Date:04/01/1990
FSC:5610
NIIN:00N042060
MSDS Number: BSSZX
Responsible Party
ATLANTA, GA 30345
US
Emergency Phone: 404-634-9100
Info Phone: 404-634-9100
Cage: 7K226
Contractor
Telephone: 404-634-9100
Cage: 7K226
Ingredients
TRICALCIUM SILICATE
CAS: 12168-85-3
OSHA PEL 5 MG/M3 (MFR)
ACGIH TLV: 5 MG/M3 (MFR)
DICALCIUM SILICATE
CAS: 10034-77-2
OSHA PEL 5 MG/M3 (MFR)
ACGIH TLV: 5 MG/M3 (MFR)
SILICA, CRYSTALLINE - QUARTZ
CAS: 14808-60-7
RTECS: VV7330000
OSHA PEL 0.1 MG/M3 RDUST
ACGIH TLV: 0.1 MG/M3 RDUST
TRICALCIUM ALUMINATE
CAS: 12042-78-3
OSHA PEL 5 MG/M3 (MFR)
ACGIH TLV: 5 MG/M3 (MFR)
TETRACALCIUM ALUMINOFERRATE
CAS: 12068-35-8
OSHA PEL 5 MG/M3 (MFR)
ACGIH TLV: 5 MG/M3 (MFR)
1)
CAS: 7778-18-9
RTECS: WS6920000
OSHA PEL 5 MG/M3 (MFR)
ACGIH TLV: 5 MG/M3 (MFR)
GYPSUM
CAS: 13397-24-5
RTECS: MG2360000
OSHA PEL 15 MG/M3;5 RESP
ACGIH TLV: 10 MG/M3
3) (SARA III)
CAS: 1344-28-1
RTECS: BD1200000
OSHA PEL 10 MG/M3TDUST;5 RESP
ACGIH TLV: 10 MG/M3 TDUST (AL)
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:CAN DRY SKIN & CAUSE ALKALI
BURNS.DUST CAN IRRIT EYES & UPPER RESP SYS.TOX EFTS NOTED IN
ANIMALS INCL ALVEOLAR DMG W/PULM EDEMA. CHRONIC: DUST CAN CAUSE
INFLAMM OF LINING TISS OF INTERIOR OF NOS E & INFLAM OF CORNEA.
EXCESSIVE INHAL OF SILICA DUST MAY RSLT IN RESP DISEASE, INCL
SILICOSIS, PNEUMOCONIOSIS (SUPDAT)
Explanation of Carcinogenicity:CRYSTALLINE SILICA:GRP 2A IARC,IARC
MONOGRAPHS, SUPPLEMENT, VOL 7,PG 341,1987. NTP 7TH ANNUAL REPORT ON
CARCIN, (SUPDAT)
Effects of Overexposure:SYMPTOMS OF EXCESSIVE EXPOSURE INCLUDE
SHORTNESS OF BREATH AND REDUCED PULMONARY FUNCTION. THIS INERT
MATERIAL GIVES NO POTENTIAL ACUTE TOXIC HAZARD. CONTAINS SILICA
PARTICLES THAT MAY BE BROKEN DOWN TO RESPIRABLE SIZE DURING
SHIPPING/USE.
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH SENSITIVE SKIN AND
WITH PULMONARY AND/OR RESPIRATORY DISEASE, INCLUDING, BUT NOT
LIMITED TO, ASTHMA AND BRONCHITIS, OR SUBJECT TO EYE IRRITATION,
SHOULD BE PRECLUDED FROM EXPOSURE.
First Aid
First Aid:EYE: IRRIGATE (FLOOD) IMMEDIATELY AND REPEATEDLY WITH CLEAN
WATER FOR AT LEAST 15 MINUTES. SKIN: WASH EXPOSED AREAS WITH SOAP
AND WATER. APPLY STERILE DRESSINGS. INHALATION: REMOVE PERSON
IMMEDIATELY TO FRESH AIR, GIVE ARTIFICIAL RESPIRATION AS NEEDED.
GET PROMPT MEDICAL ATTENTION. INGESTION: CALL MD IMMEDIATELY .
Fire Fighting
Flash Point:NONCOMBUSTIBLE
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE CONDITIONS
.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NOT EXPLOSIVE.
Accidental Release
Spill Release Procedures:USE DUSTLESS METHODS (VACUUM) AND PLACE INTO
CLOSABLE CONTAINER FOR DISPOSAL OR USED IF NOT CONTAMINATED OR WET.
USE ADEQUATE VENTILATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:PRECAUTIONS MUST BE OBSERVED BECAUSE
BURNS OCCUR WITH LITTLE WARNING--LITTLE HEAT IS SENSED.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:IN DUSTY ENVIRONMENTS, USE OF NIOSH/MSHA
APPROVED RESPIRATOR IS RECOMMENDED.
Ventilation:LOCAL EXHAUST CAN BE USED, IF NECESSARY, TO CONTROL
AIRBORNE DUST LEVELS.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:USE OF BARRIER CREAMS OR IMPERVIOUS BOOTS &
CLTHG TO PROT SKIN FROM CONT IS RECOM.EMERG EYE WASH & DELUGE (WORK
HYGIENE)
Work Hygienic Practices:FOLLOWING WORK, WORKERS SHOULD SHOWER WITH SOAP
AND WATER. OTHER PROT EQPT:SHOWER MEETING ANSI DESIGN CRITERIA .
Supplemental Safety and Health
MATERIALS TO AVOID: TETRAFLUORIDE. CONTACT WITH POWERFUL OXIDIZING
AGENTS SUCH AS FLUORINE, CHLORINE, TRIFLUORIDE, MANGANESE TRIOXIDE
AND OXYGEN DIFLUORIDE MAY CAUSE FIRES. EXPLAN OF CARCIN: 1992, ANT
IC TO BE CARCIN. HLTH HAZS: PULMONARY FIBROSIS & POSSIBLY CANCER.
HYPERSENSITIVE INDIV MAY DEV ALLERGIC DERM.
Chemical Properties
HCC:N1
Solubility in Water:SLIGHT
Appearance and Odor:GRAY COLORED WITH NO ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
IS NOT INCOMPAT W/MOST OTHER MATLS, BUT SILICA WILL DISSOLVE IN
HYDROFLUORIC ACID & PRDCE CORR GAS--SILICON (SUPDAT)
Stability Condition to Avoid:KEEP DRY UNTIL USED TO PRESERVE PRODUCT
UTILITY.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
Disposal
Waste Disposal Methods:CAN BE TREATED AS COMMON WASTE FOR DISPOSAL IN
ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.